    Loadcalc 2002 Trial Versio 1.1.1 - Service and feeder sizing calculations for single family dwellings.


Details
Size: 4.62 MB
License: Demo
OS: Win95,Win98,WinME,WinNT 3.x,WinNT 4.x,Windows2000,WinXP,Windows2003
Developer:Robert LaCapra (» more programs)
View: Antivirus Report
Download Now
Buy Now
Add to Download Basket
Program system requirements: Windows 95 or higher, 4Mb memory, 4 Mb disk space


[Zoom screenshot]


[Editor's Award]

Please select your Rating:
Awesome! Awesome! 0% [No Votes]
Very Good Very Good 0% [No Votes]
Good Good 0% [No Votes]
Average Average 0% [No Votes]
Poor Poor 0% [No Votes]
No Ratings have been Posted.

Publisher's Description:

     Loadcalc 2002 performs service and feeder sizing calculations for single family dwellings. It also prints panelboard directories in two sizes (4x6 inch and 6x8 inch) for inside the panelboard doors or covers. The 2002 National Electrical Code is fully supported.

Service/feeder load calculations for single dwelling units
Standard Calculation Method (NEC Article 220), Optional Calculation Method (NEC Article 220-30), and Additional Loads in Existing Dwelling Units Calculation Method (NEC Article 220-31).
Calculates net computed load in VA and amperes, and calculates the total service entrance load.
Panelboard Directories: Prints directories for the inside of panelboard doors.
Standard Calculation Method
Demand Factoring:
General Lighting, Small Appliance and Laundry Loads.
Cooktop, Range, Wall Oven.
Fixed Appliances.
Largest Motor Load.

Optional Calculation Method
Demand factoring of 'other loads' as per NEC 220-30.
Allows input of heating system type as per NEC Table 220-30, automatically determines the larger of heating or cooling load.

Additional Loads In Existing Dwelling Units
Load calculations for existing dwelling units presently served by a 120/240 volt or 120/208Y service.

Quick Reference Tables From The '99 NEC
Can be viewed on screen or printed.
Grounding Electrode Conductor Sizes (NEC Table 250-94).
Service/Feeder Conductor Sizes (NEC 310, Note 3).
Cooking unit demand factors (NEC 220-19).

File Save/Load
Save individual data files for later recall.
Specify default data directory
Input up to four lines of data which will print at the top of your report.

Print Preview & Printed Reports
Print preview screens show reports as they will print.
Professional, detailed printed reports.

 

 
Comments
No Comments have been Posted.
Post Comment
Name:



smiley smiley smiley smiley smiley smiley smiley smiley smiley
Disable smileys in this comment

Alerts
Your email:
Friend email:
Related downloads
Orneta Calculator for Smartphone 2002 Orneta Calculator for Smartphone 2002 1.0.2
Simple and easy to use scientific calculator for Smartphone, use at work or home
0
ABarCode for Access 2000/2002/2003 ABarCode for Access 2000/2002/2003 9.4
ABarCode lets you to print bar codes in your Access reports
0
   7OfficeTrialMacClassic 3.4
Small business sales cycle management
0
   DataConversionTools.com MDB Exporter 1.01
Export MDB file to CSV file
0
   DataConversionTools.com TABtoCSV Converter 1.01
Convert TAB files to CSV delimited files
0
   DataConversionTools.com CSVtoTAB Converter 1.01
Convert CSV files to TAB delimited files
0
   DataConversionTools.com CSVtoSQL Converter 1.01
Convert your CSV files into SQL.
0
   DataConversionTools.com CSVtoHTML Converter 1.01
Convert CSV files to HTML tables.
0
Version 2.6 Build 989 Version 2.6 Build 989 2.6
Sellers - With Automotix Instant Exchange you can sell your car(s).
0
Excel Unit Conversion Addin Excel Unit Conversion Addin 3.0
Unit Conversion Add-in for Excel that understand any unit of measure
0
Code to link to this page:
Login
Username

Password



Not a member yet?
Click here to register.

Forgotten your password?
Request a new one here.
Search Software
Subscribe RSS
Subscribe with My Yahoo!
Subscribe with NewsGator
Subscribe with My AOL
Subscribe with Bloglines
Subscribe with Netvibes
Subscribe with Google
Subscribe with Pageflakes
Featured Downloads
PrecisionID OCR-A and OCR-B Fonts 3.0

OCR-A and OCR-B Fonts.

DB Explorer

Compare two database schemas and/or table data, report differences and sync.

Fx3uInterface

The Fx3uInterface is a Serial communication driver for the Mitsubishi FX3u PLC.

Receipt Generator


SiteMech Database Manager

SiteMechanics Database Manager

Related Tags
nec
electric
electrical
calculator
contractor
engineering
service
panel
Celeb of the day


Peta Toppano